External wall panels


External wall panels for horizontal cladding

Here we provide examples of panels structure based on Scandinavian building standards. However, we can always adapt our building standards according to the country that we work in.

FOR HORIZONTAL CLADDING
250 mm THERMAL INSULATION
U < 0.16 W/m2K

19 mm CONIFER WOOD HORIZONTAL  SIDING
25 mm VENTILATED AIR GAP – planed timber laths
WIND INSULATION – DIFFUSION MEMBRANE
195 mm LOAD BEARING TIMBER STUDS
200 mm THERMAL INSULATION
0,2 mm VAPOR BARRIER – STABILIZED FILM
42 mm INTERNAL LAYER OF THERMAL INSULATION / SPACE FOR ELECTRICAL CABLES
45 mm TIMBER FRAME
12 mm DURELIS BOARDS FOR EXTRA STABILITY (mounted after assembling works)
12,5 mm GYPSUM BOARDS FOR INTERIOR FINISHING (mounted after assembling works)


External wall panel for vertical cladding

FOR VERTICAL CLADDING
250 mm THERMAL INSULATION
U < 0.16 W/m2K

19 mm CONIFER WOOD HORIZONTAL  SIDING
25 mm VENTILATED AIR GAP – planed timber laths
45 mm CROSS-LATHING
WIND INSULATION – DIFFUSION MEMBRANE
195 mm LOAD BEARING TIMBER STUDS
200 mm THERMAL INSULATION
0,2 mm VAPOR BARRIER – STABILIZED FILM
42 mm INTERNAL LAYER OF THERMAL INSULATION / SPACE FOR ELECTRICAL CABLES
45 mm TIMBER FRAME
12 mm DURELIS BOARDS FOR EXTRA STABILITY (mounted after assembling works)
12,5 mm GYPSUM BOARDS FOR INTERIOR FINISHING (mounted after assembling works)


 

External wall panel for clinker finishing

FOR CLINKER FACADE FINISHING
250 mm THERMAL INSULATION
U < 0.16 W/m2K

CLINKER FACADE FINISHING TILES
22 mm WATER-PROOF BOARD
25 mm VENTILATED AIR GAP – planed timber laths
WIND INSULATION – DIFFUSION MEMBRANE
195 mm LOAD BEARING TIMBER STUDS
200 mm THERMAL INSULATION
0,2 mm VAPOR BARRIER – STABILIZED FILM
42 mm INTERNAL LAYER OF THERMAL INSULATION / SPACE FOR ELECTRICAL CABLES
45 mm TIMBER FRAME
12 mm DURELIS BOARDS FOR EXTRA STABILITY (mounted after assembling works)
12,5 mm GYPSUM BOARDS FOR INTERIOR FINISHING (mounted after assembling works)

 


 External wall panel for plaster facade

FOR PLASTER FACADE

250 mm THERMAL INSULATION
U < 0.16 W/m2K

PLASTER FACADE FININSHING LAYER
22 mm WATER-PROOF CEMENT PARTICLE BOARD
25 mm VENTILATED AIR GAP – planed timber laths
WIND INSULATION – DIFFUSION MEMBRANE
195 mm LOAD BEARING TIMBER STUDS
200 mm THERMAL INSULATION
0,2 mm VAPOR BARRIER – STABILIZED FILM
42 mm INTERNAL LAYER OF THERMAL INSULATION / SPACE FOR ELECTRICAL CABLES
45 mm TIMBER FRAME
12 mm DURELIS BOARDS FOR EXTRA STABILITY (mounted after assembling works)
12,5 mm GYPSUM BOARDS FOR INTERIOR FINISHING (mounted after assembling works)